Park water intelligence

Pollutant loads

Flow × concentration at every sharing outlet, and which source caused a spike.

Load from sharing outlets
466 kg/d
4 outlets, last 14 days
Measured at sewer
732 kg/d
Park sewer at CETP inlet
Not traced
36 %
of the sewer load has no sharing source
Largest source
59 %
Demo Textiles

Which source caused the spike?

Chemical oxygen demand load at the Park sewer at CETP inlet reached 120 kg/h on Tue 16:00, against a usual 24 kg/h. Each outlet's load above its own baseline, 2 h earlier (sewer travel time), is ranked below.

  1. 1. Demo Textiles84 %
    205 kg above baseline
  2. 2. Demo Beverages11 %
    26 kg above baseline
  3. 3. Demo Steel Works4 %
    11 kg above baseline
  4. 4. Demo Battery Recyclers1 %
    2.1 kg above baseline
  5. 16 % of the excess could not be traced to a sharing outlet.
  • Sewer (measured)
  • Demo Textiles
  • Demo Beverages
  • Demo Steel Works
  • Demo Battery Recyclers
  • Spike at the sewer

Daily Chemical oxygen demand load by source

  • Demo Textiles
  • Demo Beverages
  • Demo Steel Works
  • Demo Battery Recyclers

Sources ranked

TenantFlowMean conc.LoadSharePeak
Demo Textiles455 m³/d578 mg/L275 kg/d59 %80 kg/h · Tue 13:00
Demo Beverages414 m³/d329 mg/L140 kg/d30 %16 kg/h · Wed 14:00
Demo Steel Works356 m³/d112 mg/L41 kg/d9 %4.4 kg/h · Tue 13:00
Demo Battery Recyclers105 m³/d84 mg/L9.2 kg/d2 %1.0 kg/h · Fri 13:00

Load = flow × concentration (m³/h × mg/L ÷ 1000 = kg/h). Laboratory results are held for 36 h between samples. Not sharing Chemical oxygen demand data with the park: Demo Foods, Demo Plastics.