How much CO₂ can this formation hold, and how much will the pressure allow?

Give the formation as ranges: low, most likely and high. The screener works out the capacity by volume with the US DOE method, the CO₂ density at the formation's depth from the Span–Wagner equation of state, and the largest amount the wells can inject before the pressure nears the fracture pressure or the weakest fault. It draws every range 2,000 times and gives P10, P50 and P90.

In short: KAI-GeoEnergy's free CO₂ Storage Capacity Screener estimates how much CO₂ a saline formation or depleted field can hold (US DOE volumetric method, Span–Wagner CO₂ density within 1 % of NIST) and how much of that the pressure allows before the rock nears its fracture pressure or a fault. It draws every uncertain input 2,000 times and gives P10, P50 and P90. Screening, not bankable engineering.

Simulate the plume, pressure and trapping (sign in) →

The formation

Each range is low, most likely and high (a triangle drawn 2,000 times). Give one number in all three for a fixed value.

Area (km²)Area (km²)
Thickness (m)Thickness (m)
Porosity (fraction)Porosity (fraction)
Net to grossNet to gross
Permeability (mD)Permeability (mD)
Fracture gradient (MPa/km)Fracture gradient (MPa/km)
Storage efficiency, density and faults

How much CO₂ it can hold

P10P50P90
Capacity (the smaller of the two)2.37 Mt4.13 Mt6.89 Mt
By volume (DOE method)2.88 Mt11.5 Mt33.8 Mt
Allowed by the pressure2.67 Mt4.41 Mt7.17 Mt
DOE volumetric with the most likely inputs2.6 Mt10.2 Mt27.6 Mt
Largest rate per well0.0220.0370.06 Mt/yr

At the formation: 70 °C, 15.1 MPa; CO₂ 510 kg/m³ (Span–Wagner table), viscosity 37.6 µPa·s; brine 0.516 mPa·s. The pressure may rise 8.01 MPa; it limits the capacity in 79 % of the draws.

  • Note: Pressure limits the capacity in 79 % of the draws: more wells, brine production or a longer injection period would store more.
  • Note: Screening estimate: volumetric (DOE method) and a single-phase pressure estimate. Not bankable engineering; a two-phase simulation is the next step.

Screening estimate (KAI CO₂ Storage Capacity Screener). Not a measurement or a reserve. P10 is the low value.

How to use it

  1. 1. Describe the formation

    Saline formation or depleted field, rock type, and whether it is a closed compartment or extends far.

  2. 2. Give the ranges

    Low, most likely and high values for area, thickness, porosity, permeability and the fracture gradient.

  3. 3. Set the depth and the wells

    Mid depth, temperature and pressure gradients, salinity, the number of wells and the injection period.

  4. 4. Read the capacity

    Capacity by volume and as allowed by the pressure, P10 / P50 / P90, and the largest rate per well.

  5. 5. Check the notes

    Whether the CO₂ is dense, whether the pressure is the limit, and what the estimate leaves out.

  6. 6. Simulate the plume

    Signed in, queue a two-phase CO₂ injection run in the Reservoir Lab for the plume, the pressure and the trapping.

Questions and answers

How is CO₂ storage capacity estimated?

By volume first: G = A × h × φ × ρ(CO₂) × E, the area, thickness and porosity of the formation, the density of CO₂ at its depth, and a storage efficiency E that says how much of the pore space CO₂ can really fill (US DOE method, Goodman et al. 2011). For saline clastic formations the published E is 0.51 %, 2.0 % and 5.4 % at P10, P50 and P90.

Why can the pressure limit capacity?

Injected CO₂ pushes brine aside and raises the pressure. In a closed compartment, or with too few wells, the pressure reaches the rock's fracture pressure (or wakes a fault) long before the pore space is full. The screener works out the largest rate each well can take for the whole injection period and compares the total with the volume.

Where does the CO₂ density come from?

From a table of the Span and Wagner (1996) equation of state, the same equation NIST uses. At 24 check points between 10 and 150 °C and 9 to 30 MPa it agrees with NIST's WebBook within 0.01 %. Near the critical point (31 °C, 7.4 MPa) density changes very fast and the screener says so.

Is this bankable?

No. It is a screening estimate: volumetric with published efficiency factors, and a single-phase pressure estimate that uses the brine's viscosity, which overstates the pressure near the wells. A two-phase simulation with site data (the Reservoir Lab's CO₂ runs), then a field study, are the next steps.

What does the Utsira reference case show?

The Norwegian CO₂ Storage Atlas (NPD 2011) gives the Utsira and Skade aquifer a pore volume of 5.26 × 10¹¹ m³, a storage efficiency of 4 % and a CO₂ density of 0.75 t/m³, so 15.77 Gt. With those inputs the screener gives 15.78 Gt.

Are my numbers stored?

No. The screener runs in your browser and sends nothing.

How it works

Saline formations: G = A · h · φ · NTG · ρ(CO₂) · E, with E from Goodman et al. (2011), Table 8 (clastics 0.51 / 2.0 / 5.4 %, dolomite 0.64 / 2.2 / 5.5 %, limestone 0.40 / 1.5 / 4.1 % at P10 / P50 / P90). Depleted fields: G = A · h · φ · (1 − Swi) · ρ(CO₂) · E with your own E. E is drawn along a straight line through its P10, P50 and P90 in ln E.

CO₂ density and viscosity come from a table of the Span–Wagner equation of state (through CoolProp), read by bilinear interpolation of their logarithms; it covers dense CO₂ from 5 to 150 °C and 7.5 to 60 MPa and is checked against 24 NIST points (largest difference 0.003 %). The pressure limit is a single-phase estimate with the brine's viscosity: Theis for an open formation, or the larger of Theis and pseudo-steady state in each well's share of a closed compartment, against the chosen share of the fracture pressure and, when given, the pressure change that wakes the weakest fault.

The same code runs in the KAI engine; shared test vectors keep the two equal. Two-phase flow, dissolution and the plume's shape need a simulation: the Reservoir Lab's CO₂ runs do that in open-DARTS.

Sources

By KAI Water & Energy (Kampala, Uganda). Reviewed 28 November 2026. A first look for planning: a hydrogeologist confirms every drilling decision.