KAI
Menu
The worked examples are synthetic and say so. The real-data case below is Utah FORGE (public DOE data). Your own readings never leave your browser.

KAI-GeoEnergy · Well Test Studio · live preview

Measure the reservoir, then model it: well tests and DFITs

A well test measures the rock at reservoir scale: permeability-thickness, skin, boundaries and, from a DFIT, the closure pressure that estimates the minimum horizontal stress. Paste the readings and the rates; the studio draws the derivative, labels the flow regimes, fits the models with their range and lists every model that fits as well.

In short: KAI-GeoEnergy's free Well Test Studio reads a pressure-transient test or a DFIT in the browser. It draws the Bourdet derivative with flow-regime labels, fits wellbore storage and skin, dual porosity, a radial composite, faults, a closed circle and fractures with P10–P90, lists every model that fits as well, and picks DFIT closure on the G-function as a Shmin estimate.

The Utah FORGE case ↓ · How it is checked ↓ · Keep your tests in the lab (sign in) →

1. The readings and the rates

Time and pressure, one reading per line, with a header that names the units (time_h, pressure_bar; psi, kPa or MPa work; clock times and dates too). Keep the readings from before the rate changed: the start pressure is read from them.

217 readings · 2 rate steps

Worked example (synthetic, made by the studio's own radial composite model with 300 Pa of gauge noise): 20 mD over 100 m, skin 2, a cooled zone of 60 m with mobility ratio 0.21: 60 kg/s of 40 °C water for 24 h, then a 24 h falloff.

2. The rock and the water

Water at 40 °C and 150 bar (IAPWS-IF97): 998.6 kg/m³, 0.655 mPa·s, compressibility 0.0000425 1/bar. Total compressibility 0.0000925 1/bar. For an injection falloff the cooled zone around the well is the inner region: give the injected water's temperature, and read the outer region through the composite model's M.

3. The diagnostic plot

  • Check: The derivative never flattens: radial flow was not reached (or is masked). kh from this test is not determined; the fitted kh rests on the model's shape alone.
Smoothing window LBuildup/falloff: derivative on superposition time
  • 0.0026–0.032 h: Wellbore storage (unit slope) (slope 0.92)
  • 0.5–6.6 h: Derivative falling: a constant-pressure boundary, or more mobile fluid farther out (hot water beyond a cooled zone) (slope -0.96)
  • The labels read the derivative's slope; they are suggestions to check against the models, not an interpretation.

No flat derivative: kh is not determined by a straight line. The fitted kh below rests on the model's shape.

4. Models, fitted with their range

Models to fit

Real data: Utah FORGE minifracs and a stimulation falloff

Public U.S. Department of Energy data (Geothermal Data Repository, CC BY 4.0): the 16B(78)-32 minifracs (GDR 1570, report GDR 1596) and the 16A(78)-32 stage 1 falloff (GDR 1379, analysis GDR 1408). Thresholds set before the analysis: ISIP within 3.0 %, closure within 5.0 %.

  • ISIP agrees with the report in 15 of 15 cycles (median misfit 0.2 %).
  • Closure agrees in 10 of 12 cycles where the studio picks one (median 0.5 %); the others are shown below with their misfit.
  • 16A stage 1: no closure on the G-function, as in the published analysis; surface ISIP 3,990 psi against 4,020 psi (-0.6 %).
  • Not compared: MF6/3, MF7/1 (no shut-in with that cycle's volume in the labelled record).
Test / cycleISIP report / studio, psimisfitclosure report / studio, psimisfitshape
MF-1/14536 / 4,5500.2 %4526 / 4,5400.2 %tip extension
MF-1/24421 / 4,420-0.0 %4423 / 4,4200.0 %tip extension
MF-2/13312 / 3,300-0.3 %3288 / 3,060-6.9 %pressure dependent
MF-2/23249 / 3,2600.3 %3237 / 3,2400.2 %tip extension
MF-2/33327 / 3,330-0.0 %3323 / 3,3300.1 %tip extension
MF-3/12747 / 2,7500.2 %2745 / 2,740-0.0 %tip extension
MF-3/22891 / 2,880-0.2 %2853 / 2,8801.0 %normal
MF-4/13328 / 3,3400.2 %3315 / none–not closed
MF-4/23597 / 3,590-0.1 %3568 / 3,390-5.0 %normal
MF-4/33588 / 3,6301.1 %3556 / 3,350-5.7 %pressure dependent
MF-5/13262 / 3,2700.1 %3250 / none–not closed
MF-5/23620 / 3,620-0.1 %3620* / none–height recession
MF-6/13476 / 3,4900.3 %3473 / 3,4800.1 %tip extension
MF-6/33418 / ––3405 / none–not matched
MF-7/13359 / ––3346 / none–not matched
MF-7/23450 / 3,4500.1 %3450* / 3,420-0.8 %tip extension
MF-7/33475 / 3,4800.1 %3479 / 3,440-1.1 %normal

* no bi-linear pick in the report: compared with its ISIP-method value. Downhole gauge in the straddle interval (absolute or gauge pressure not stated in the file).

  • 16B pressures are the downhole Quartzdyne gauge in the straddle interval; the file does not say absolute or gauge pressure.
  • A cycle runs from the first injection to the first flowback after it (shut-in at least 2 minutes); each report cycle is matched, in order, to the next cycle in the record whose injected volume is within 20 % of the report's.
  • The report's closure picks compared are its bi-linear (pressure-decay) values; where it has none, its ISIP-method value.
  • 16A stage 1 is a surface record (no bottom-hole correction is verified), so only the G-function shape and the surface ISIP are compared; the CSM permeability (0.492 mD, linear flow on bottom-hole pressure) is not reproduced here.

The notebook that checks every number →

How the studio is checked: 13 of 15 benchmarks pass

Each pass rule was written and committed before the first run. A benchmark that fails stays failed and is shown here; the model it tests is not claimed as checked by it.

BenchmarkRuleResult
Theis line source and Cooper–Jacob: the same physics as the Pumping Test Studio
Theis, C.V.
max relative error of the inverted line source against ½·W(1/(4tD)) ≤ 1e-4 for tD from 10 to 1e8; semi-log transmissivity equal to the Pumping Test Studio's within 1e-9 relative
line source against ½·W(1/4tD), max relative error: 0.0000000767 (≤ 0.0001)
semi-log T against the Pumping Test Studio's Cooper–Jacob T: 0 (≤ 0.000000001)
pass
Agarwal, Al-Hussainy and Ramey (1970): wellbore storage and skin
Agarwal, R.G., Al-Hussainy, R.
for CD = 1e3 and S = 0, 5, 10: early (tD/CD ≤ 1e-2) |pD/(tD/CD) − 1| ≤ 0.02; late (tD ≥ 10·(60 + 3.5S)·CD) |pD − (½(ln tD + 0.80907) + S)| / pD ≤ 2e-3 and |tD·dpD/dtD − ½| ≤ 0.01
early unit slope |pD/(tD/CD) − 1|: 0.00435 (≤ 0.02)
late radial line, relative: 0.00169 (≤ 0.002)
derivative plateau |d − ½|: 0.0186 (≤ 0.01)
fail
Gringarten et al. (1979) and Bourdet et al. (1983): the CD·e^2S type curves
Gringarten, A.C., Bourdet, D.P., Landel, P.A.
CD·e^2S = 1e8 with (CD, S) = (1e2, ½ln 1e6) and (1e4, ½ln 1e4): max |Δ(pD − S)| / (pD − S) ≤ 0.02 for tD/CD from 0.1 to 1e3, and the derivatives tD·dpD/dtD within 0.02 relative
max |Δ(pD − S)| / (pD − S): 4.2 (≤ 0.02)
max relative difference of the derivatives: 0.00132 (≤ 0.02)
fail
Storage and skin: the derivative plateau, read late enough (corrected rule, 29 Nov 2026)
Agarwal, R.G., Al-Hussainy, R.
for CD = 1e3 and S = 0, 5, 10: at tD = 100, 1,000 and 10,000 × (60 + 3.5S)·CD, |tD·dpD/dtD − ½| ≤ 0.01
derivative plateau |d − ½|: 0.0019 (≤ 0.01)
pass
The CD·e^2S type curves, compared on pD as published (corrected rule, 29 Nov 2026)
Gringarten, A.C., Bourdet, D.P., Landel, P.A.
CD·e^2S = 1e8 with (CD, S) = (1e2, ½ln 1e6) and (1e4, ½ln 1e4): max |ΔpD| / pD ≤ 0.02 for tD/CD from 0.1 to 1e3, and the derivatives tD·dpD/dtD within 0.02 relative
max |ΔpD| / pD: 0.000502 (≤ 0.02)
max relative difference of the derivatives: 0.00132 (≤ 0.02)
pass
Warren and Root (1963): dual porosity
Warren, J.E.
ω = 0.01, λ = 1e-7, S = 0, no storage: early (tD from 1e2 to 1e3) |pD − ½(ln(tD/ω) + 0.80907)| / pD ≤ 0.01; late (tD ≥ 1e10) |pD − ½(ln tD + 0.80907)| / pD ≤ 2e-3 for both pseudo-steady and transient interporosity flow
early fissure line, relative: 0.000803 (≤ 0.01)
late total-system line, relative (both): 0.000000365 (≤ 0.002)
pass
One sealing fault by an image well: the derivative doubles
Horner, D.R.
LD = L/rw = 500, S = 0, no storage: |pD − (pD,homogeneous + ½·W(LD²/tD))| / pD ≤ 1e-4 for tD from 1e2 to 1e9; derivative at tD ≥ 100·LD² within 0.02 of 1
against homogeneous + image ½·W(LD²/tD), relative: 0.0000000008 (≤ 0.0001)
late derivative |d − 1|: 0.00498 (≤ 0.02)
pass
Gringarten, Ramey and Raghavan (1974): a vertical fracture
Gringarten, A.C., Ramey, H.J.
early (tDxf ≤ 1e-3) |pD/√(π tDxf) − 1| ≤ 0.02 and log-log slope within 0.02 of ½; late (tDxf ≥ 1e3) |pD − line| / pD ≤ 0.01 for both
early |pD/√(π tDxf) − 1|: 0.0000000004 (≤ 0.02)
early log-log slope |s − ½|: 0.000000005 (≤ 0.02)
late radial lines, relative: 0.0017 (≤ 0.01)
pass
Radial composite: the cold-water bank around an injector
Satman, A., Eggenschwiler, M.
M = F = 1: |pD − pD,homogeneous| / pD ≤ 1e-6; M = 4, F = 1, RD = 100: inner plateau (tD from 1e2 to 1e3) within 0.02 of ½ and outer plateau (tD ≥ 1e8) within 0.04 of M/2
M = F = 1 against homogeneous, relative: 0 (≤ 0.000001)
inner plateau |d − ½|: 0.0131 (≤ 0.02)
outer plateau |d − M/2|: 0.000301 (≤ 0.04)
pass
Closed circle: pseudo-steady state
Earlougher, R.C.
reD = 1000, S = 0, no storage: at tD from 1e7 to 1e8 |pD − (2tD/reD² + ln reD − ¾)| / pD ≤ 2e-3
pseudo-steady line, relative: 0.00000127 (≤ 0.002)
pass
Two Laplace inversions agree (Stehfest against Talbot)
Stehfest, H.
max relative difference ≤ 1e-3 on every model at every vector point (Stehfest at N = 12 is accurate to about 1e-4 on smooth monotone solutions)
max relative difference, Stehfest N = 12 against Talbot M = 32: 0.000106 (≤ 0.001)
pass
Independent Python implementation (kai-engine) against this library
kai-engine tools/welltest_vectors.py: mpmath inverse Laplace (Talbot) and scipy Bessel functions, written separately from the TypeScript..
every value within 1e-4 relative
type curves (23 × 20 points): 0.0000000008 (≤ 0.0001)
Bourdet derivative (12 series): 0 (≤ 0.0001)
G-function: 0 (≤ 0.0001)
water ρ, cp, μ, c: 0 (≤ 0.0001)
pass
IAPWS-IF97 region 1 and IAPWS 2008 viscosity: the published check values
IAPWS R7-97(2012), Revised Release on the IAPWS Industrial Formulation 1997 for the Thermodynamic Properties of Water and Steam, Table 5.
region 1 v and cp within 1e-8 relative; viscosity within 1e-7 relative
IF97 region 1 v and cp, relative: 0.0000000028 (≤ 0.00000001)
viscosity beyond the published rounding, relative: 0 (≤ 0.0000001)
pass
Round trip: synthetic tests with noise, gauge resolution and a clock offset
KAI (2026), this benchmark.
for each of kh, S and C the true value lies inside the reported P10–P90 in at least 80 % of the 200 trials
k: share of trials with the truth inside P10–P90: 0.83 (≥ 0.8)
S: share of trials with the truth inside P10–P90: 0.84 (≥ 0.8)
C: share of trials with the truth inside P10–P90: 0.87 (≥ 0.8)
pass
DFIT: a synthetic G-function test with a known closure
Nolte, K.G.
closure pressure recovered within 5 % of the net pressure at shut-in (ISIP − closure) on 3 synthetic tests (normal, pressure-dependent leak-off, tip extension)
closure error as a share of the net pressure (worst of 3): 0.000982 (≤ 0.05)
pass
What KAI-GeoEnergy models, and what it doesn't · from a first look to a bankable-ready field study

Free

First look

The browser preview is a first look on a small grid; plan on the engine run.

Starter

Screening

One doublet layout on your data: will it deliver, and with what range?

Professional

Pre-feasibility

Layouts and rates compared before you drill. For a bankable report, take it to a Field study.

Premium

Bankable-ready feasibility

Scoped with you as a fixed-price project on your own site data, with independent review and sign-off by a KAI reservoir engineer. What is not modelled below stays out unless the scope adds and proves it.

Not modelled in any plan today

  • Two-phase flow, steam and high-enthalpy fields (such as volcanic fields of the East African Rift)
  • Two-way stress–permeability coupling, fault rupture and earthquake prediction (coupled runs give bounds and estimates)
  • Reactive transport: scaling, dissolution and mineral precipitation
  • CO₂ storage: in build until its benchmarks pass
  • Underground hydrogen storage: in build until its benchmarks pass

First-look, screening and pre-feasibility results are for decisions before drilling. A bankable report adds your site data, independent review and sign-off by a KAI reservoir engineer: the Field study.

Updated 2026-11-29. Plans and prices: KAI website.

How to use it

  1. 1. Paste the readings

    Time and pressure, with a header naming the units, including the readings from before the rate changed.

  2. 2. Give the rate history

    Each rate with the time it started, 0 for a shut-in; tick injection test for an injector.

  3. 3. Describe the rock and the water

    Net thickness, porosity, wellbore radius and rock compressibility; the water's properties come from the temperature and pressure.

  4. 4. Read the derivative

    The log-log plot and the flow-regime labels show what the test can and cannot tell.

  5. 5. Fit the models

    Tick the models to try; read k, kh, skin and the distances with their P10–P90, and every model that fits as well.

  6. 6. Hand the numbers on

    Open k in the Reservoir Lab, or a DFIT's closure and pore pressure in the Fault Stability Screener.

Questions and answers

What is the Bourdet derivative?

The rate of change of the pressure with the logarithm of time, Δp′ = dΔp/d ln t, smoothed over a window L of log time (Bourdet et al. 1989). On a log-log plot each flow regime has its own slope: 1 for wellbore storage, 0 (flat) for radial flow, ½ for linear flow, ¼ for bilinear flow.

How are kh and skin worked out?

In radial flow the derivative is flat at qμ/(4πkh), so its level gives kh. The skin comes from how far the pressure change sits above the radial line. The studio fits whole models to the pressure and the derivative together, and checks the straight line on the semi-log plot.

What does it mean when the derivative doubles?

A derivative that steps up to twice its flat level means half the flow is cut off: one sealing fault, at a distance the time of the step tells. A derivative that falls means pressure support, from a constant-pressure boundary or, in an injector, from more mobile hot water beyond the cooled zone.

Why do several models fit?

Well-test interpretation is not unique: a fault, a composite and a dual-porosity reservoir can draw nearly the same curve over the time a test lasts. The studio lists every model within 10 % of the best misfit, with its own P10–P90, so the choice rests on geology, not on the curve alone.

How is the P10–P90 range worked out?

Two ways, and the wider is shown: the linearised interval from the fit's covariance, and a residual bootstrap of 30 resampled records, each refitted. On 200 synthetic tests with noise, gauge resolution and a clock offset the true k fell inside it in 83 % of trials.

How is closure picked in a DFIT?

On the G-function plot, G·dP/dG follows a straight line through the origin while the fracture is open and leaks off normally. Closure is where the pressure leaves that line (Barree et al. 2009). The closure pressure is the estimate of the minimum horizontal stress, Shmin.

Has it been tested on real data?

Yes, on public Utah FORGE data: its ISIP agrees with the 16B(78)-32 minifrac report within 3 % in 15 of 15 cycles and its closure within 5 % in 10 of 12, and it agrees there is no closure in the 16A(78)-32 stage 1 falloff. The misfits are published.

What does it not do?

Gas tests (pseudo-pressure), horizontal wells, finite-conductivity fractures, layered reservoirs and numerical models are not covered yet. Two of its benchmarks failed the rules set before they were run, and are shown on the page. Those two rules were mis-set; corrected rules, added beside them as new benchmarks, pass.

How it works

Every model is written in Laplace space as the reservoir's response g(s) to a unit rate; wellbore storage and skin are added there (Agarwal, Al-Hussainy and Ramey 1970) and the result is inverted numerically by Stehfest (N = 12) for the fit, with a fixed Talbot contour as the check. Rate histories are superposed in time; buildups and falloffs use superposition time for the derivative. Boundaries are image wells; the closed circle and the radial composite are exact.

The fit is Levenberg–Marquardt on log Δp and the log derivative, the derivative weighted by the two scatters, with the readings' clock offset as a parameter. The P10–P90 range is the wider of the linearised interval and a 30-resample residual bootstrap. The water's density, viscosity and compressibility come from IAPWS-IF97 and IAPWS 2008 at the temperature and pressure given.

Not covered yet: gas (pseudo-pressure), horizontal wells, finite-conductivity fractures, layered reservoirs and numerical models.

Sources

By KAI Water & Energy (Kampala, Uganda). Reviewed 29 November 2026. A first look for planning: a hydrogeologist confirms every drilling decision.