HydroSaaS · borehole monitoring · reference case
Will San Antonio's index well cross the next drought stage?
J-17 is one borehole in Bexar County, Texas, 874 ft deep into the Edwards (Balcones Fault Zone), San Antonio segment aquifer. When its 10-day average falls past set lines, pumping cuts follow across the San Antonio region. We put it on HydroSaaS like any client borehole, forecast it, and rebuilt the public model of the aquifer behind it.
1. Where the level is going: the next six months
A response model learns how J-17 answers rain over the recharge zone. The forecast is then run with every winter's rain since 1950 (76 winters), and each run carries the model's own typical error (1,520 paths in all). The shaded band holds 8 in 10 of them.
- Measured J-17 (weekly mean of daily highs)
- Middle path
- 8 in 10 outcomes (P10–P90)
- Drought stage lines
| End of | Dry (P10) | Middle (P50) | Wet (P90) |
|---|---|---|---|
| Dec 2026 | 640.8 ft | 647.7 ft | 654.8 ft |
| Jan 2027 | 639.4 ft | 648.6 ft | 657.0 ft |
| Feb 2027 | 639.0 ft | 648.5 ft | 658.9 ft |
| Mar 2027 | 638.2 ft | 649.0 ft | 661.4 ft |
| May 2027 | 637.3 ft | 650.8 ft | 665.1 ft |
Chance that the 10-day average falls below a stage line at some point: Stage 3 (640 ft) 23% by 28 February and 35% by 31 May; Stage 4 1% and 4%. Chance of being back above 650 ft on 31 May: 53%. The Authority's stages also look at Comal and San Marcos spring flow, which this model does not forecast.
2. Is it any good? Tested on years it never saw
The model was fitted on 1985–2018 only. Then, from the first of every month in 2019–2026, it forecast 90 days ahead with only the rain known up to that day, and we compared the band with what J-17 actually did. Half of a rain pulse's effect on J-17 arrives within about 18 months and the tail lasts years, which is why the level changes slowly and why "no change" is hard to beat over three months. The band is the useful part: it says how far a dry or wet winter can move the well.
- What J-17 did 90 days later
- Forecast made 90 days earlier: middle
- and band (P10–P90)
3. The whole aquifer: a public model rebuilt in MODFLOW 6
A single-well model cannot say what a pumping cut in Uvalde does to Comal Springs. For that we rebuilt the Texas Water Development Board's public GWSIM-IV model of the San Antonio segment (Report 340) in MODFLOW 6: 862 active cells on a 31 × 80 grid, 60 cell faces closed by faults, 10 springs and the Medina Lake leakage, driven month by month by the recorded pumping (365–544 thousand acre-feet a year) and recharge of 1978–1989. Nothing was re-tuned: it is the published model, converted.
J-17: measured and MODFLOW 6 (ft above sea level)
Comal Springs: measured and MODFLOW 6 (cfs)
- Measured
- MODFLOW 6 (converted public model)
What it is good for now: the timing and size of the aquifer's swings, and spring flow at Comal. What it is not yet: a model to set limits with. It is a coarse grid (cells of 0.9–5 miles), it runs low at J-17 in wet years and low at San Marcos, and the files of the newer USGS MODFLOW model of the region are not in the public download. Next: carry it forward to 2026 with the Authority's yearly pumping and the USGS recharge estimates, then recalibrate.
What this means for your borehole
The same three steps work on any borehole with a level record: HydroSaaS watches the readings against the pump intake or a safe level, a response model says how far the weather can move it in the coming months, and where the aquifer is mapped, a groundwater model answers "what if we pump more?".
Data and sources
- J-17 daily water levels · Edwards Aquifer Authority, via Texas Water Development Board (Water Data for Texas) · Public data
- Daily rain and temperature · NOAA NCEI, GHCN-Daily · Public domain (US Government)
- Comal and San Marcos spring flow · USGS, gauges 08168710 and 08170000 · Public domain (US Government)
- GWSIM-IV Edwards model and Report 340 · Texas Water Development Board, Groundwater Availability Models · Public data
- Stage lines (J-17 10-day average) · Edwards Aquifer Authority, Critical Period Management · Public information
Record 1932-11-12 to 2026-11-21 (33,545 days). Lowest 612.5 ft on 1956-08-17; highest 703.3 ft on 1992-06-14. Model: Pastas 2.0 response model, FlexModel (non-linear soil store), double exponential; rain from the mean of 6 NOAA GHCN-Daily stations: Prade Ranch, Sabinal, Boerne, Bulverde, Fischers Store, San Antonio airport; evaporation by Hargreaves from San Antonio airport temperatures. Built 2026-11-25. Not an official forecast: the Edwards Aquifer Authority declares the stages.